For water damage restoration and mold remediation at room temperature, use a low grain refrigerant (LGR) dehumidifier. Size it by dividing the drying chamber's cubic feet by the class factor (100, 50 or 40) to get total AHAM pints per day. In cold or very dry spaces, use a desiccant. INLINE Distributing sells Dri-Eaz, Phoenix and INLINE Force One units rated 64 to 170 AHAM pints, plus the Dri-Eaz DriTec 4000i desiccant.

Dehumidifier sizing calculatorSolicitar cotizaciónDepartamento de pedidos 1-800-795-0933Find a branch

INLINE Force One 85 LGR dehumidifier
INLINE Force One 85 LGR dehumidifier

At a glance

  • LGR sizing: cubic feet divided by the class factor (100, 50, 40 and 40 for classes 1 to 4) gives total AHAM pints per day.
  • Desiccant sizing: cubic feet times air changes per hour (1, 2, 3 and 3 by class), divided by 60, gives the airflow needed in CFM.
  • Compare units on AHAM pints (80°F, 60% RH). The Dri-Eaz LGR 5000Li lists 80 at AHAM and 164 at saturation (90°F, 90% RH).
  • Listed amp draws on INLINE's refrigerant and LGR units run from 4.7 (Dri-Eaz DrizAir 1400) to 10 (INLINE Force One LGR 155).
  • The Dri-Eaz DriTec 4000i desiccant moves about 395 CFM and can run on its back in low crawl spaces.
  • Order online, paste or upload part numbers on the Quick Order page, send a list through the quote form, or call 1-800-795-0933.

Dehumidifiers INLINE sells, side by side

Each row gives the type, pints per day with the condition the maker states (AHAM, saturation or none given), airflow in CFM, amp draw and weight, linked to the product page. Compare rows on the AHAM column and treat a figure with no stated condition as a ceiling. Replacement filters and the Injectidry drip pan follow the table.

Dehumidifiers by maker and model, with type, water removal, airflow, power and weight
DeshumidificadorTipoPints per dayAirflowPowerPeso
PhoenixPhoenix 250 MAXTipoLGRPints per day145 at AHAMAirflow365 CFMPower120 V, 8.2 APeso119 lb
INLINEINLINE Force One LGR 155TipoLGRPints per day155 at AHAMAirflow300 CFMPower10 APeso88 lb
ASDASD-155TipoLGRPints per day155 at 80°F, 60% RHAirflow300 CFMPower10 APesoNot listed
PhoenixPhoenix DryMAX XL ProAlso in redTipoLGRPints per day135 at AHAMAirflow300 CFMPower110 to 120 V, 6.7 APeso85 lb
Dri-EazDri-Eaz LGR 7000XLiAlso in blackTipoLGRPints per day130 at AHAMAirflow280 CFMPower115 V, 8.8 APeso106 lb
PhoenixPhoenix R250TipoLGRPints per day130 at AHAMAirflow310 CFMPower120 V, 7.4 APeso109 lb
PhoenixPhoenix DryMAX XLAlso in redTipoLGRPints per day125 at AHAMAirflow300 CFMPower110 to 120 V, 7.7 APeso85 lb
Dri-EazDri-Eaz LGR 3500TipoLGRPints per dayUp to 170 at AHAMAirflowNot listedPowerNot listedPesoNot listed
Dri-EazDri-Eaz LGR 6000LiAlso in blackTipoLGRPints per day100 at AHAMAirflow320 CFMPower115 V, 6.5 APeso99 lb
INLINEINLINE Force One LGR 85TipoLGRPints per day85 at AHAM, 154 at 90°F, 90% RHAirflow206 CFMPower5.77 APeso70 lb
ASDASD-85Also in redTipoLGRPints per day85 at 80°F, 60% RHAirflow206 CFMPower5.77 APesoNot listed
Dri-EazDri-Eaz LGR 5000LiTipoLGRPints per day80 at AHAM, 164 at 90°F, 90% RHAirflow215 CFMPower115 V, 5.1 APeso69 lb
Dri-EazDri-Eaz RevolutionTipoLGRPints per day80 at AHAMAirflow180 CFMPower115 V, 5.5 APeso63 lb
PhoenixPhoenix DryMAX BLEAlso in redTipoLGRPints per day80 at AHAMAirflow170 CFMPower120 V, 5.5 APeso63 lb
Dri-EazDri-Eaz LGR 2800iTipoRefrigerantPints per day130 at AHAM, 200 at 90°F, 90% RHAirflow160 CFMPower115 V, 8 APeso160 lb
Dri-EazDri-Eaz DrizAir 1400TipoRefrigerantPints per day64 at AHAM, 130 at 90°F, 90% RHAirflow215 CFMPower115 V, 4.7 APesoNot listed
Dri-EazDri-Eaz DrizAir 1200TipoRefrigerantPints per dayUp to 120, conditions not statedAirflowNot listedPowerNot listedPesoNot listed
Dri-EazDri-Eaz DriTec 4000iTipoDesiccantPints per dayUp to 118, conditions not statedAirflow395 CFMPowerNot listedPesoNot listed

Figures as each maker lists them on the product page. AHAM is the 80°F, 60% RH rating condition; compare units at the same condition, since water removal depends on the temperature and humidity of the space.

Dehumidifier filters and parts

LGR vs desiccant vs conventional dehumidifier for each job condition

All three pull water vapor out of the air; they differ in where they stop working. A conventional refrigerant unit, such as the Dri-Eaz DrizAir 1200, condenses water on a cold coil, and its removal falls off as the air dries because the coil can no longer get far enough below the air's dew point. An LGR unit precools incoming air before the main coil, so it keeps condensing at the low grain levels where a drying job finishes. A desiccant unit, the Dri-Eaz DriTec 4000i, adsorbs vapor into a drying material that is heated to release it, so it does not depend on a cold coil.

The tradeoff is power. Reactivation heat (PTC heaters on the DriTec) costs more energy per pint than an LGR in warm, damp air, so a desiccant earns its place when the air is cold, the materials are dense, or an LGR has stalled.

Dehumidifier type by job condition
Job conditionTypeINLINE example
Job conditionWarm room, wet carpet, pad and drywallTypeLGRINLINE examplePhoenix DryMAX XL, Dri-Eaz LGR 6000Li
Job conditionOne room on a shared circuitTypeCompact LGR or refrigerantINLINE examplePhoenix DryMAX BLE, Dri-Eaz DrizAir 1400
Job conditionLarge open commercial floorTypeXL LGRINLINE exampleDri-Eaz LGR 3500, Phoenix 250 MAX
Job conditionHot attic or summer building over 100°FTypeHigh-temperature LGRINLINE examplePhoenix 250 MAX (to 125°F)
Job conditionUnheated space below about 65°FTypeDesiccantINLINE exampleDri-Eaz DriTec 4000i
Job conditionHardwood, plaster, slab, heavy timberTypeDesiccant, or LGR with heatINLINE exampleDri-Eaz DriTec 4000i
Job conditionLGR readings flat for a dayTypeAdd desiccantINLINE exampleDri-Eaz DriTec 4000i

AHAM vs saturation pints per day, and ratings with no condition

AHAM is 80°F at 60% RH; saturation is 90°F at 90% RH. Air at the saturation point holds roughly twice the water, about 195 grains per pound against about 93, so saturation figures run near double: the Dri-Eaz DrizAir 1400 lists 64 and 130. Neither is what a unit pulls on day three in a drier chamber. Size and compare on AHAM, and only compare units rated at the same condition.

Some figures carry no test point at all. The LGR 6000Li lists 219 pints and the LGR 7000XLi 235 in high humidity with no temperature or RH given, and the DriTec 4000i lists 118 under standard conditions it does not define. Keep those out of sizing math.

Ratings as INLINE's product pages state them
UnitAHAM pintsOther figure on its page
UnitDri-Eaz LGR 5000LiAHAM pints80Other figure on its page164 at saturation
UnitINLINE Force One LGR 85AHAM pints85Other figure on its page154 at saturation
UnitDri-Eaz LGR 2800iAHAM pints130Other figure on its page200 at 90°F, 90% RH
UnitDri-Eaz LGR 6000LiAHAM pints100Other figure on its page219, high humidity, no test point
UnitDri-Eaz LGR 7000XLiAHAM pints130Other figure on its page235, high humidity, no test point
UnitPhoenix 250 MAXAHAM pints145Other figure on its page31 gallons maximum, no test point
UnitDri-Eaz DriTec 4000iAHAM pintsNot givenOther figure on its page118, undefined standard conditions

Pints, CFM and grain depression: why equal ratings dry differently

Pints per day is airflow times grain depression. A working conversion: pints per day equals CFM times grain depression times about 0.0148 (1,440 minutes a day, 0.075 pounds of air per cubic foot, 7,000 grains per pound of water, about 1.04 pounds per pint). Run it backward on INLINE's records. The Dri-Eaz LGR 2800i makes 130 AHAM pints on 160 CFM, about 55 grains of depression. The Phoenix DryMAX XL makes 125 on 300 CFM, about 28 grains.

High airflow turns the chamber's air over faster. Deep depression gives drier outlet air per pass, which pays off when you duct it into a wall cavity, under cabinets or beneath a tented floor. Read inlet and outlet grains per pound with a thermo-hygrometer, or on the display: the LGR 6000Li and 7000XLi show grain depression onboard, and Phoenix DryMAX units log readings to the DryLINK app. When the gap narrows and chamber GPP stops falling day over day, the unit has hit its floor. Add heat, tighten the chamber or bring in a desiccant.

Commercial dehumidifier sizing by cubic feet and class

Measure only the area you close off as the drying chamber: length times width times ceiling height. Assign the class by how much of the combined floor, wall and ceiling surface is wet and how dense it is, then divide cubic feet by the factor below for refrigerant or LGR units, or multiply by air changes per hour and divide by 60 for a desiccant. Round up to whole units. This is the opening setup; first-day readings decide whether to add capacity.

  • Class 2 first floor, 30 x 50 ft, 8 ft ceiling: 12,000 cu ft divided by 50 is 240 pints. Two Phoenix DryMAX XL (250) cover it; conventional units at factor 40 would need 300 pints.
  • Class 3 basement, 25 x 40 ft, 8 ft: 8,000 cu ft divided by 40 is 200 pints. Two Dri-Eaz LGR 6000Li (200), or a Phoenix 250 MAX with a DryMAX BLE (225).
  • Class 3 crawl space, 40 x 50 ft, 3 ft high: 6,000 cu ft times 3, divided by 60, is 300 CFM. One DriTec 4000i at about 395 CFM covers it.
Initial dehumidification factors by class
ClassWhat is wetConventionalLGRDesiccant ACH
Class1What is wetUnder about 5% of surfaces, low porosityConventional100LGR100Desiccant ACH1
Class2What is wetAbout 5% to 40% of surfaces, carpet and padConventional40LGR50Desiccant ACH2
Class3What is wetOver 40%, often soaked from aboveConventional30LGR40Desiccant ACH3
Class4What is wetDense materials holding deep waterConventionalNot usedLGR40Desiccant ACH3

Dehumidifier sizing calculator

Enter the drying chamber you close off, pick the class of water loss and a unit. The math is the method on this page: cubic feet divided by the class factor for refrigerant or LGR units, or cubic feet times air changes per hour divided by 60 for a desiccant.

Class of water loss
Dehumidifier type
Chamber volume
12,000 cu ft
AHAM pints per day needed
240
AHAM pints per day
Units of this model
2
Phoenix DryMAX XL
Total amps
15.4 A

30 x 50 x 8 ft = 12,000 cu ft. 12,000 divided by 50 = 240 AHAM pints per day.

240 divided by 125 per Phoenix DryMAX XL = 1.92, rounded up to 2.

Circuits at about 80% load (12 A on a 15 A circuit, 16 A on a 20 A): 2 on 15 A circuits (1 per circuit), or 1 on 20 A circuits (2 per circuit). Count the air movers on the same circuits too.

Conventional units at factor 40 would need 300 pints for the same chamber.

Same job with other models

  • 2 xDri-Eaz LGR 7000XLi at 130 AHAM pints each, 260 pints in all, 17.6 A total, 2 on 20 A circuits
  • 2 xPhoenix R250 at 130 AHAM pints each, 260 pints in all, 14.8 A total, 1 on 20 A circuits
  • 2 xPhoenix DryMAX XL Pro at 135 AHAM pints each, 270 pints in all, 13.4 A total, 1 on 20 A circuits
  • 2 xPhoenix 250 MAX at 145 AHAM pints each, 290 pints in all, 16.4 A total, 2 on 20 A circuits

This is the opening setup. First-day readings decide whether to add capacity, and units come out as materials reach their dry goal. Size and compare on AHAM pints; a figure with no stated condition is kept out of the count.

See the Phoenix DryMAX XL, or request a quote for this setup.

Using a dehumidifier for mold remediation

A dehumidifier controls moisture; it does not remove mold already growing. Within the remediation plan it lowers relative humidity in the containment and dries framing, sheathing and subfloor left in place, taking away the moisture that fed the growth. The filter on a dehumidifier (Dri-Eaz 4-PRO, Phoenix MERV 10 or MERV 11) protects the coil; it is not a HEPA stage, so it does not take the place of an air scrubber.

Negative air adds a moisture load. A scrubber exhausting 500 CFM out of the containment pulls 500 CFM of make-up air in. If that air comes from outdoors at 80°F and 60% RH (about 93 grains) into a containment held near 55 grains, the load is about 500 x 38 x 0.0148, roughly 280 pints a day, more than any single unit INLINE sells removes at AHAM. Run negative air at the lowest airflow that holds the pressure differential your project specification sets, and draw make-up air from conditioned space where the plan allows.

  • Stop the water source first. Drying a wall that is still getting wet only burns days.
  • Build containment and start negative air before aggressive airflow. Most plans hold air movers off moldy surfaces until that material is removed or cleaned.
  • Set the humidistat to the plan's target. The Dri-Eaz LGR 5000Li, DrizAir 1400, LGR 2800i, LGR 3500 and DriTec 4000i offer humidistat control.
  • Run the condensate hose to a drain outside the work area so water never pools inside the containment.
  • Confirm framing is dry with a moisture meter before any mold-resistant coating goes on.
  • Change the dehumidifier filter before the unit moves to the next job.

Crawl space and basement dehumidifiers after water damage

Height decides what fits through the access: the Dri-Eaz Revolution stands 17.6 in tall, the Phoenix DryMAX XL and DryMAX BLE 17-1/2 in, and the DriTec 4000i runs on its back. Otherwise leave the unit outside and duct in. The DryMAX XL outlet takes two 10 in lay-flat ducts or one 14 in; the 250 MAX takes a 12 in flex intake and 10 in lay-flat supply; the LGR 6000Li and 7000XLi outlets fit 12 in lay-flat.

Check the listed low end against the space. The Revolution, LGR 6000Li, LGR 7000XLi and Phoenix units list 33°F; the INLINE Force One and ASD units list 41°F. Running inside the range is not the same as pulling much water: near the bottom, coils approach freezing and units cycle through defrost. In a cold crawl, the desiccant is the better tool. Below grade, plan the drain first; the LGR 3500's built-in pump pushes through its 40 ft hose even from below-grade spaces, its page says.

How many dehumidifiers per circuit, hose length and filters

Plan on loading a breaker to about 80% of its rating for equipment that runs around the clock: 12 amps on a 15 amp circuit, 16 on a 20. Count the air movers on the same circuit, and remember draw climbs in hot, wet rooms. Water damage restoration equipment works whole rooms through by circuit.

Drain hose: the Dri-Eaz LGR 5000Li, DrizAir 1400, LGR 6000Li, LGR 2800i and LGR 3500 list 40 ft; the Phoenix DryMAX XL and BLE store a 33 ft hose on board; the 250 MAX has an internal pump with 30 ft. Over finished floors, set the unit in a 25 x 25 in, 7 gallon Injectidry Protect-It pan.

Filters: the Dri-Eaz 4-PRO on the Dehumidifier Filters shelf fits the LGR 7000XLi, LGR 5000Li, DrizAir 1400 and DrizAir 1200, with a separate one for the Revolution. Phoenix pleats go by size: 12 x 14 x 1 in MERV 10 for the DryMAX XL and XL Pro, 9 x 12 x 1 in MERV 10 for the BLE, 12 x 12 x 1 in MERV 11 for the R250 and 16 x 20 x 2 in MERV 11 for the 250 MAX.

Units per circuit at 80% load, by listed amps
UnitAmpsPer 15 APer 20 A
UnitDri-Eaz DrizAir 1400Amps4.7Per 15 A2Per 20 A3
UnitDri-Eaz LGR 5000LiAmps5.1Per 15 A2Per 20 A3
UnitPhoenix DryMAX BLEAmps5.5Per 15 A2Per 20 A2
UnitINLINE Force One LGR 85Amps5.77Per 15 A2Per 20 A2
UnitDri-Eaz LGR 6000LiAmps6.5Per 15 A1Per 20 A2
UnitPhoenix DryMAX XLAmps7.7Per 15 A1Per 20 A2
UnitPhoenix 250 MAXAmps8.2Per 15 A1Per 20 A1
UnitINLINE Force One LGR 155Amps10Per 15 A1Per 20 A1

Dri-Eaz vs Phoenix dehumidifiers, compared by spec

Both lines cover compact to XL LGR sizes; the choice usually comes down to the app your crew already uses, the filters you want to carry and the air movers you run. The Phoenix DryMAX XL Pro lists compatibility with Phoenix AirMAX, AirMAX BLE and Focus II air movers. INLINE's own Force One LGR 85 (85 AHAM pints, 206 CFM, 5.77 amps, 70 lbs) and stackable Force One LGR 155 (155 pints, 300 CFM, 10 amps, 88 lbs) sit alongside both. Compare them all on the LGR dehumidifiers shelf.

Dri-Eaz and Phoenix side by side, from INLINE's product pages
PointDri-EazPhoenix
PointAHAM rangeDri-Eaz64 to 170 pintsPhoenix80 to 145 pints
PointMonitoringDri-EazCommand Hub, Bluetooth and Wi-Fi on newer unitsPhoenixBluetooth, DryLINK app
PointFilterDri-Eaz4-PRO multi-stage on mostPhoenixMERV 10 or MERV 11 pleated
PointRefrigerantDri-EazR32 where listedPhoenixR-410A or R-454B by unit
PointTop operating temperatureDri-Eaz100°F where listedPhoenix100°F to 125°F
PointDrain hoseDri-Eaz40 ft on mostPhoenix33 ft on DryMAX, 30 ft pump hose on 250 MAX

Questions contractors ask

Why is the saturation rating on a dehumidifier so much higher than the AHAM rating?

Because air at 90°F and 90% RH holds about twice the water of air at 80°F and 60% RH, so the coil condenses more per hour. The Dri-Eaz LGR 5000Li lists 80 pints at AHAM and 164 at saturation. Real chambers sit nearer AHAM and get drier each day, so size on the AHAM figure.

Is a dehumidifier with a higher pint rating always faster?

No. Pints per day reflects airflow and grain depression at one test condition, and the finish of a job depends on how dry the outlet air stays as the room dries. The Dri-Eaz LGR 2800i makes 130 pints on 160 CFM, so it delivers much drier air per pass than the Phoenix DryMAX XL, which makes 125 pints on 300 CFM.

Which commercial dehumidifiers can be stacked for transport and storage?

The Dri-Eaz LGR 5000Li and DrizAir 1400 move two units together and stack three high for storage, their pages say. The Dri-Eaz Revolution, Phoenix DryMAX XL, DryMAX XL Pro, DryMAX BLE, Phoenix R250 and INLINE Force One LGR 155 also list stackable housings. The Phoenix 250 MAX and Dri-Eaz LGR 6000Li and 7000XLi pages do not.

Can I run a dehumidifier inside a mold containment?

Yes, most remediation setups run one inside the containment to hold humidity at the plan's target while negative air runs. Size it for the humid make-up air the scrubber pulls in, route its hose to a drain outside the work area, and change the dehumidifier filter before the unit goes to another job.

Will a dehumidifier get rid of mold?

No. A dehumidifier lowers relative humidity and dries damp materials, but it does not remove mold already growing on a surface. Remediation also means fixing the water source and removing or cleaning affected material as the plan directs. For discoloration left after cleaning, see the mold and mildew stain removers shelf.

What is the best dehumidifier for mold remediation?

A compact LGR or refrigerant unit with a humidistat suits most containments at room temperature, because it holds a set humidity without overrunning. The Dri-Eaz LGR 5000Li and DrizAir 1400 add app control, and the LGR 2800i and LGR 3500 have automatic humidistats. In cold or already dry air, use the desiccant DriTec 4000i.

Can you over-dry a room with too many dehumidifiers?

Yes. Driving hardwood, plaster or millwork well below its normal moisture content can crack or cup it. Set a humidistat, pull units as materials reach their dry goal, and read unaffected material with a meter for comparison. The DriTec 4000i takes minimum and maximum humidity settings, which its page says help avoid over-drying.

Do I need a dehumidifier with a pump, or will it drain by gravity?

You need a pump whenever the drain sits above the unit or across a long run, which covers most basements and upper floors. Gravity works only with a floor drain or sink lower than the outlet. The Phoenix 250 MAX has an internal pump with 30 ft of hose, the Dri-Eaz LGR 3500 pumps through 40 ft even below grade, and the DryMAX BLE and R250 list condensate pumps.

Última revisión